Shenzhen Yehai Technology Development Co., Ltd.
Main products:Multimeter,Infrared Thermometer,Instrument Meter
Products
Contact Us
  • Contact Person : Ms. jiang rosas
  • Company Name : Shenzhen Yehai Technology Development Co., Ltd.
  • Tel : 86-0755-26509606
  • Fax : 075526502620
  • Address : Guangdong,shenzhen,Nanshan district
  • Country/Region : China

Loop Calibrator

Loop Calibrator
Product Detailed
Volt/mA Process Calibrator High Accuracy Process Calibrator mV mA Source Output Loop Power Output

Loop Calibrator :

  

***Basic  Functions: 

• DC voltage: 20.000V/200.00V±0.1%rdg• Milli voltage: 200.00mV±0.1%rdg• DC current:  22.000mA/20.000mA±0.05%rdg• Current source/simulate:  22.000mA/20.000mA±0.05%rdg• Voltage source/simulate:  20.000mV/100.00mV/10.000V±0.05%rdg 

•  Loop power output:   24V dc

 ***Special Functions: • • X1/X10/X100 Rotary potentiometers continuously adjustable

•  Clear LCD max.display 19999 counts with backlight  

***Environment Characteristics: 

•    Relative humidity: not higher than 75%• Environment temperature: 23±5°C• Storage Temperature: -20°C~60°C (relative humidity <=80%) 

***General  Characteristics: 

•  Power:   rechargeable 9V battery,  Charger

•  Product color:  Yellow and Black

•  Product size : 200* 100* 40mm •  Product Net Weight: 600g

•  Standard Accessories:   Test Leads,  Chargeable battery, Charger, User Manual, gift box

•  Standard Individual Packing:   gift box

•  Standard Quantity Per Carton: 10pcs

•  Standard Carton Meas: 58*46*22mm

•  Standard Carton Gross Weight: 13.0kg

***Applications: 

•  Apply for  testing basic electronic parameter

•  Apply for  calibrating the accuracy of the other instrument meter

•  Apply for  on-site process calibrating & controling in industrial field

***WARRANTY:    one year

  ------------------------------------------------------------------

Technical Specifications:

FunctionRangeResolutionAccuracy
Current  Measuring 0~20mA1μA±(0.05% +3Lsd)
0~22mA10μA±(0.05% +3Lsd)
Voltage  Measuring 0~200.00mV10uV ±(0.1% +3Lsd) 
0~20V 1mV ±(0.1% +3Lsd) 
0~200V 10mV±(0.1% +3Lsd) 
 DC Voltage signal output10V1mV±(0.05% +3Lsd)
20mV1μV±(0.05% +3Lsd)
100mV10μV±(0.05% +3Lsd)
 DC Current signal output20mA1μA±(0.05% +3Lsd)
22mA10μA±(0.05% +3Lsd)
Loop Power Output   24V

  ------------------------------------------------------------------------------------

 -----------------------------------------------------------------------------------------

-------------------------------------------------------------------

Manufactory  Tour:

  

-------------------------------------------------------------------

Shipment & Feedback:

Loop Calibrator



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.